Specifications
for Standard Pre-Assembled Buildings
|
|
|
|
Structural |
|
Electrical |
|
|
|
All
structural components to be extruded aluminum
6063-T5 alloy. Base to be 4" x 3" x 3/16" angle (4"
structural channel used on buildings larger than 8'x12',
buildings with no floor and two piece buildings); corner
posts to be 3" x 3" x 3/8" grooved angle; grooved
intermediate tees to be 3" x 2 1/8" x 3/8" ; top
angle to be 2 1/2" x 2 1/2" x 3/16". |
|
All
conduit and wiring will be surface-mounted and
installed in accordance with the National Electrical Code
and carrying the IBEW label. Conduit is 3/8" or 1/2" mc
cable and wire is #14. Included is a 100 amp circuit
breaker box with a 70 amp main and three circuit
breakers; fluorescent lighting, 110 volt, 15 amp duplex
outlet, 220 volt, 20 amp single outlets and 15 amp
switches as shown on drawings. Fixtures, heaters, etc.,
carry the UL label. |
|
|
Welding |
|
|
|
All
structural components to be certified welded at all
intersections to create a unitized framework. No rivets,
bolts or other fasteners shall be used in joining structural
components. |
|
|
|
Should
your local code not be in agreement with the National
Electrical Code, it is your responsibility to notify us. Other types
of electric ( 20 amp outlets, 3/4" conduit, #12 wire, etc.) are
available. Consult us for pricing and lead-time. |
|
|
|
|
Miscellaneous |
Wall
Panels |
|
|
|
|
Complete
building with optional outside roof shall be
watertight and interior commercial shelf to be furnished
on buildings no more that 48" wide. Floor-to-ceiling
height will be approximately 6' 10 3/8", overall height
to be 89" and with optional roof, approximately 92" |
|
|
Panels
to be minimum of 1/2" Medexâ„¢ laminated on
both sides with .030" fiberglass reinforced plastic. Panels
will be attached the structural members with fasteners not
exposed on the building exterior. |
|
|
|
|
|
|
Floor |
|
|
|
Integral
Roof Option |
|
|
Flooring
to consist of one layer of 5/8" particle board and
one layer of 5/8" plywood underlayment as the core with
a vapor barrier on the exterior surface. Interior surface
shall be aluminum tread plate on buildings up to and
including 48" wide and vinyl tile on all other buildings. |
|
|
|
|
Factory
installed integral roof to consist of 5/8" plywood
with vapor barrier on the exterior surface. Buildings
larger than 4' by 8' to receive two layers of 5/8"
plywood. Roofs to include aluminum gutters around the
entire perimeter. |
|
|
|
|
|
Ceiling |
|
|
|
Outside
Roof Options |
|
|
Ceiling
to be minimum 5/8" white vinyl-faced particle board. |
|
|
|
|
“K-D"
outside roof shipped for assembly and installation
on site by others. Decking to be standing seam formed,
pre-finished white aluminum, nominal 12" wide panel,
.028" thick. Roofs with overhangs larger that 12" to have
reinforcing angles included. Perimeter to be extruded
aluminum fascia and gutter trim. |
|
|
Windows |
|
|
|
Windows
to be heavy-duty sliding, lockable and pile
weather stripped. Glass to be minimum 1/8" clear
tempered safety glass. |
|
|
|
Doors |
|
|
|
|
Options |
|
|
Swing
doors to be 20 gauge steel, 1 3/4" thick with
threshold and 2' x 2' window with minimum 1/4" clear
tempered safety glass. Hinges to be 1 1/2 pair 4 1/2" x
4 1/2". Lockset to be commercial quality, lever type;
closer to be spring type; and frame to have continuous
vinyl gasket. Sliding doors to be aluminum, painted white,
fully weather-stripped and lockable. Upper portion to be
glazed with minimum 1/4" clear, tempered safety glass
and lower portion to have a solid panel with matching
interior and exterior surfaces. |
|
|
|
|
Many options are
available including outside roofs with
various overhangs; custom roofs and fascias; painted,
thermal insulation for floor, ceiling or walls; tinted, wire,
polycarbonate, insulated or Plexiglass; fork-liftable; and
heating or air conditioning units. |
|
|